Storage Tanks LIN – LOX – LAR
Storage tanks for :
LIN – liquid nitrogen
LOX – liquid oxygen
LAR – liquid argon
- Regulations on dimensioning and construction: EN 13458 – ATTACHMENT C, ASME (U STAMP) and GOST
- Operating pressure: 5 – 7 bar (MAWP)
- Design temperature: +50°C / -196°C
- Ambient temperature: +50°C / -50°C
- Material of inner tank: stainless steel according to design codes
- Material of outer tank: stainless steel or aluminium according to regulations on construction
- Radiographic examination: conform to regulations on dimensioning
- Fluid permeability: conform to regulations on dimensioning
- Isolation: Vacuum and Perlite insulation
- Optimised dispatch
- Valve group in the lower part
- Optimised sound level
- High-quality lacquering due to oven drying
- Non-destructive screening methods according to norms (radiographic examination, penetration test, magnetic particle testing etc.)
- Manufacturing autorisation and operating licence according to directive 2014/68 / EU for pressure equippment (PED) according to EN 13458 – Attachment C, AD 2000-Code, ASME (U STAMP), GOST