Vertical compressors
Vertical industry compressors
COMPRESSORS DESIGNED FOR YOUR REQUIREMENTS
To meet the strict requirements of the industrial gases, offers Corken various performance of vertical oil-free piston compressors. Based on customer-specific demands is each model availabe with a double (D-Style) or a triple (T-Style) sealing. A single-stage- and two-stage vertical compressor are also available like dry-running- or lubricated models.
To increase the flexibilty of the vertical compressors, offers Corken its customers also water-cooled models. This water cooling allows to significantly reduce the process temperature. Therfore, those can also be used in fields of applications with a high K-value. Gases with a high K-value are for example argon, helium, hydrogen, air and nitrogen.
Single sealed single stage vertical compressors
Cylinder bore (mm) |
76,2 |
76,2 |
101,6 |
114,3 |
114,3 |
Stroke (mm) |
63,5 |
63,5 |
76,2 |
101,6 |
101,6 |
Piston displacement (m³ / h) Minimum 400 (UPM) Maximum 825 (UPM) |
7,0 14,3 |
13,9 28,7 |
29,7 61,2 |
50,1 103,3 |
96,3 198,8 |
Maximum working pressure (bar) |
23,1 |
23,1 |
23,1 |
23,1 |
31;0 |
Maximum power (kW) |
5,6 |
15 |
15 |
35 |
45 |
Max. Load of piston rod (kg) |
1633 |
1633 |
1814 |
3175 |
3175 |
Max. Outlet temperature (° C) |
+177 |
||||
Min. Inlet temperature (° C) |
-32 |
||||
Net weight of the unit (kg) |
68 |
96 |
177 |
338 |
409 |
Maximum flow - propane (m³ / h) |
11,4 b |
22,9 b |
48,8 b |
82,0 b |
157,6 b |
ANSI / DIN flange connection option |
Yes |
Yes |
Yes |
Yes |
- |
Double and triple sealed single stage vertical compressors
D-style |
D91 |
D291 |
D491 |
D491-3 |
D691 |
D691-4 |
D891a |
T-style |
T91 |
T291 |
T491 |
T491-3 |
T691 |
T691-4 |
T891a |
First stage [mm, Ø]
|
76.2 |
76.2 |
101.6 |
76.2 |
114.3 |
101.6 |
114.3 |
Stroke (mm) |
63.5 |
63.5 |
76.2 |
76.2 |
101.6 |
101.6 |
101.6 |
Stroke volume m³ / h |
7.0 |
13.9 |
29.7 |
16.7 |
50.1 |
39.6 |
96.3 |
14.3 |
28.7 |
61.2 |
34.5 |
103.3 |
81.6 |
198.8 |
|
Max. Working pressure (bar) |
23.1 |
23.1 |
23.1 |
41.4 |
23.1 |
41.4 |
31.0 |
Max. Power (kW) |
5.6 |
11 |
11 |
11 |
26.1 |
26.1 |
34 |
Max. Load on the piston rod (kg) |
1,633 |
1,633 |
1,814 |
1,814 |
3,175 |
3,175 |
3,175 |
max. outlet-temperature (°C) |
177 |
||||||
Weight (kg) |
68.0 |
95.2 |
176.9 |
176.9 |
337.9 |
337.9 |
408.2 |
ANSI/DIN Flange Option |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
– |
Optional water cooling |
– |
– |
– |
– |
Yes |
Yes |
– |
Double and triple sealed two-stage vertical compressors
D-style |
FD151 |
D191 |
FD351 |
D391 |
WFD551 |
D590 |
FD591 |
D791a |
T-style |
FT151 |
T191 |
FT351 |
T391 |
WFT551 |
T590 |
FT591 |
T791a |
First stage [mm, Ø] |
63.5 |
76.2 |
69.9 |
114.3 |
101.6 |
152.4 |
152.4 |
152.4 |
Second stage [mm, Ø] |
31,8 |
44,5 |
44,5 |
63,5 |
63,5 |
82,5 |
82,5 |
82,5 |
Stroke (mm) |
63.5 |
63.5 |
76.2 |
76.2 |
101.6 |
101.6 |
101.6) |
101.6 |
Stroke volume m³ / h |
4.76 |
7.0 |
7.0 |
18.9 |
19.7 |
44.5 |
44.5 |
89.0 |
10.0 |
15.2 |
14.4 |
38.7 |
42.1 |
91.7 |
91.7 |
179.8 |
|
Max. Working pressure (bar) |
82.8 |
41.4 |
82.8 |
41.4 |
69.0 |
23.1 |
41.4 |
41.4 |
Max. Power (kW)
|
11 |
11 |
11 |
11 |
26.1 |
26.1 |
26.1 |
34 |
Max. Load on the piston rod (kg) |
1,633 |
1,633 |
1,814 |
1,814 |
3,175 |
3,175 |
3,175 |
3,175 |
Max. Outlet temperature (°C) b |
177 |
|||||||
Weight (kg) |
97.5 |
97.5 |
154 |
158.8 |
369.7 |
358.8 |
358.8 |
421.9 |
ANSI/DIN Flange Option |
Yes |
Yes |
Yes |
Yes |
Yes |
– |
Yes |
– |
Optional water cooling |
– |
– |
Yes |
Yes |
Yes |
Yes |
Yes |
– |
a = Double acting compressor
b = 177 ° C outlet temperature requires special O-rings, such as PTFE or Viton. The highest recommended temperature with Buna N or Neoprene O-rings is 120 ° C
Please note: Special applications may reduce the performance of the compressor. Please contact our staff for review.